NEC 2023 electrical planning
Size the circuit.
See the limits.
Calculate wire, conduit, breakers and load for EV charging, solar interconnections and subpanel feeders.
Calculators
Eight worksheets with live results and export.
Conduit fill
Check the smallest trade size for mixed conductors, see the cross-section, and export a wire and conduit takeoff.
625 · 310.16 · 250.122EV charger circuit
Translate a Level 2 charging setpoint into a breaker, a temperature-limited conductor and an equipment ground estimate.
215 · 225 · 250.32 · 310.16Subpanel feeder
Size a 120/240 V four-wire feeder for a garage, workshop or RV panel, with copper and aluminum run comparisons.
705.12(B)(2) · NEC 2023Solar busbar 120% rule
Check the load-side headroom for PV and battery backfeed and see which panel layouts need a different review.
Ch. 9 · Table 9AC voltage drop
Estimate end-of-run voltage with AC impedance, then compare conductor sizes at your chosen drop target.
310.15 · 310.16Ampacity derating
Work through insulation ampacity, ambient and bundle factors, and the terminal cap for one conductor.
220.82 · Optional methodDwelling service load
Build a dwelling-load worksheet with the first 10 kVA at 100%, HVAC demand, and a separate EVSE planning allowance.
690.8 · 705.28 · Product listingsMicroinverter AC branch
Check 240 V microinverter counts, trunk ratings, branch current and the combined breaker floor.
Worked guides
Open a common job scenario with the numbers filled in.
Conduit fill8 guides
- How many 10 AWG THHN wires fit in ½-inch EMT?
- 10 AWG THHN fill in ¾-inch EMT
- ¾-inch vs. 1-inch EMT for 6 AWG THHN
- EMT fill for two 6 AWG wires and one 10 AWG ground
- ¾-inch PVC Schedule 40 vs. 80 conduit fill
- LFNC-B fill for two 6 AWG XHHW-2 wires
- 8 AWG THHN vs. XHHW-2 in ¾-inch EMT
- Conduit fill for three 4 AWG XHHW-2 and a ground
EV charger circuit8 guides
- 60 A Tesla Wall Connector wire and conduit size
- 32 A EV charger wire size on a 40 A breaker
- 40 A Level 2 EV charging on a 50 A circuit
- 48 A EVSE with 6 AWG NM-B vs. THWN-2
- ChargePoint Home Flex 50 A hardwire circuit sizing
- 80 A Level 2 EVSE on a 100 A circuit
- 208 V wire sizing for a 32 A Level 2 charger
- NEMA 6-50 vs. 14-50 for a plug-in EV charger
Subpanel feeder7 guides
- 100 A garage subpanel at 200 ft: aluminum vs. copper
- 60 A detached garage subpanel wire size
- 125 A workshop feeder wire size at 150 ft
- 150 A aluminum feeder: 3/0 XHHW-2 at 125 ft
- 200 A feeder: 4/0 vs. 250 kcmil aluminum
- SER vs. XHHW-2 vs. MHF for a 100 A feeder
- Four-wire feeder, ground rods and disconnect for a detached shop
Solar busbar 120% rule6 guides
AC voltage drop5 guides
Ampacity derating5 guides
Dwelling service load6 guides
- 100 A service load for a small electric home
- 120 A calculated dwelling load: 125 A or 150 A service?
- 150 A dwelling service load with an EV charger
- 200 A service load with EV charging and a heat pump
- Heat pump auxiliary heat with a 220.82 interlock
- 400 A service planning for a large dwelling with two EVSEs
Check the assumptions
Every worksheet includes its equation, code references and installation constraints.